back button black v05

MEMS Capacitive vs Piezoresistive Pressure Sensors – What are their differences?

MEMS Capacitive vs Piezoresistive Pressure Sensors – What are their differences?

20 January 2021

Pressure sensors are regarded as one of the most commonly used sensor types, as they are responsible for measuring any applied force on gases or liquids, which is then expressed as an electrical signal. They can have various applications like for example in medical devices and the healthcare industry, automation, hydraulics, as well as aeronautics. The majority of the pressure sensors currently installed in the field are based on MEMS technology and utilize either piezoresistive or capacitive measurement principle. In this article, we will be discussing their main differences and we will be highlighting the advantages of each.

Piezoresistive technology measurement principle

The term piezoresistive is composed by the Greek word “piezo” (meaning squeeze or press) and resist. In piezoresistive sensors, four resistors are placed on a silicon diaphragm in order to measure the result of strain or physical pressure applied upon them. Any perceptible change in resistance is being converted, through a Wheatstone bridge circuit into an output voltage. The piezoresistive pressure measurement principle is one of the firstly developed in MEMS technology and it was developed many years before the capacitive one. As a result, it is most commonly used. Due to their widespread and low production cost, piezoresistive pressure sensors are widely used in consumer electronics and the automotive industry, as well as in household appliances.

Piezoresistive technology measurement principle

Capacitive technology measurement principle

Two parallel and electrically isolated conducting plates are needed to ensure that a capacitive pressure sensor operates efficiently. The bottom plate is fixed while the top one is sensitive to pressure changes. When pressure is applied, the top plate (or membrane) bends and a capacitance Δ is created. This variation in capacitance is then translated to an electrical signal where it can be read and conditioned by an ASIC or microcontroller.

Capacitive technology measurement principle

Where is MEMS capacitive technology best applied?

MEMS capacitive technology is best applied to applications where accuracy, reliability and safety are of paramount importance. This is due to the technical advantages derived from the properties of the MEMS elements, which are similar to those of the standard passive components (resistors, capacitors), as well as due to differences in design and fabrication methods.

Technology comparison, capacitive vs piezoresistive

In comparison to piezoresistive sensors, capacitive pressure sensors offer many advantages. Even though they may require more complex signal conditioning circuits and calibration algorithms, they have higher accuracy and lower total error band. Moreover, capacitive pressure sensors have low power consumption since there is no DC current flowing through the sensor element due to its nature. Thus, very low power sensing systems, can be designed and implemented that require only a small bias to the circuit by an external reader, making them ideal for remote or implanted medical applications. The table below summarizes the pros and cons of the MEMS capacitive pressure sensors with respect to the piezoresistive ones.

Technology comparison, capacitive vs piezoresistive

MEMS capacitive pressure sensors also offer excellent long-term stability. This is a design attribute. As illustrated above, a typical MEMS capacitive pressure sensor element features two sense and two reference capacitors. The reference capacitors are not sensitive to pressure variations. The pressure calculation is performed using the following algorithm.

pressure calculation

Long term stability is mainly affected by the aging of the sensing elements and therefore the drift in measurement accuracy over time.

Due to the layout of capacitive dies, the sense and reference capacitors are exposed to the same environment. That means that they are exposed to the same conditions and stimuli that cause aging to the sensors and therefore long-term drift. Since the sense and reference capacitors are exposed to the same conditions and are manufactured using the same materials and procedures, they also age with the same rate. Therefore, utilizing the pressure calculation algorithm and the layout of the MEMS die, the long-term drift effect is minimized and therefore an excellent long-term stability is achieved.

Last but not least, the major advantage of MEMS capacitive technology over piezoresistive is the overpressure tolerance (proof pressure and burst pressure). Due to their design, MEMS capacitive sensors can withstand up to 100x the rated pressure. This happens due to the fact that the sensor architecture consists of a fixed bottom plate and a suspended membrane which deforms with pressure. When overpressure is applied the deformation reaches the bottom membrane and inevitably stops without breaking. At the same time due to the distance traveled and the stresses exerted there are no plastic deformations. This translates into an unaffected sensor performance after the release of the overpressure.

Touch mode example pressure sensors

In the table and figures that follow, you can see an example of the overpressure performance of a 2bar absolute calibrated sensor. The sensor’s Maximum Expected Operating Pressure (MEOP) is 2 bars. The sensor is measured at a reference pressure of 1.2 bar abs and then pressurized at the following pressure steps as indicated below.

overpressure performance pressure sensors

Sensor reference measurement, pressure sensors

Is capacitive technology ideal for overpressure?

As explained above, whenever overpressure is applied to automation equipment, conventional pressure sensors could get damaged. For that reason, sensors based on silicon capacitive process technology could be used. Understanding the advantages of capacitive technology and the various ways it can be applied to pressure sensors is important and could lead to increased productivity and lower maintenance costs. ES Systems has designed pressure sensors with capacitive technology that can offer high performance and precision along with great efficiency and reliability at a competitive cost.

Are capacitive pressure sensors ideal for medical applications?

Medical applications can be enhanced by MEMS capacitive pressure sensors, as they could provide very high accuracy and long-term stability. More specifically, they are extremely tolerant in overpressures making them suitable for use in applications where measurement safety is critical and sensor repair is not an option.

The cutting-edge MEMS capacitive technology can be applied in demanding environments regarding absolute, gauge, relative, or differential pressure measurements. For this reason, ES Systems offers three families of high-end capacitive pressure sensors. These families are:

  • ESCP-MIS1, designed to sustain high measurement quality in harsh environments and media
  • ESCP-BMS1, ideal for industrial, medical and HVAC applications that require high accuracy and low total error band
  • ESCP-MIT1, a pressure transmitter suitable for applications with harsh environmental conditions where resistance to corrosive fluids or gases is required